Skip to main content
Getz Network

Backup-power-aware charging

Charging capped at your backup-power limit during load-shedding

Most sites switch EV charging off when Eskom or the municipality cuts supply, because chargers could overload the inverter. For each outage on the site’s calendar, Getz Network caps charging at a backup-power limit your installer specifies, so cars can keep charging at a lower rate within what the backup system can carry.

When the grid goes down, charging drops to what the backup can carry.

  1. What you see: the outage rule, the 30 kW backup limit and the battery reserve
  2. Why it matters: during an outage, charging is capped at the backup-power limit you configure

What it does

How charging behaves during an outage

The limit is yours, sized with your installer for the inverter, battery or generator on site.

  • A limit per site

    Set the backup-power limit for each site’s continuity policy, sized with your installer for the inverter, battery or generator.

  • Planned outages on record

    Your team enters Eskom or municipal outage windows, or they are created from work orders, for one site or many.

  • Sessions slow down, not stop

    During the outage the EV budget is the backup-power limit, shared across the cars charging. New arrivals share the same budget.

  • Back to normal afterwards

    When the outage window ends, the next recalculation returns the budget to the grid-headroom rules.

  • Load-shedding schedule import

    Published schedules become planned outages without anyone typing them in.

    Coming soon

  • Edge controllers for offline sites

    A site keeps authorising and charging through a network outage.

    Coming soon

In the product

Planned outages next to the continuity policy

Outages are listed per site with their windows. Operations staff can see which sites are on a backup limit right now, and the energy team can review every charging-profile change made because of it.

Planned outages and load-shedding windows, shared with roaming partners.

  1. What you see: upcoming windows per site
  2. Why it matters: drivers’ apps show the outage before they drive there

Interactive: an outage, step by step

A morning of Eskom load-shedding at one site

Step through a planned outage at a fictional site with a 30 kW backup-power limit. The chart shows the EV charging budget through the morning.

Illustration · synthetic values
Outage window0 kW30 kW60 kW90 kW120 kWBackup-power limit 30 kW07:0009:3010:0011:0012:3013:00

On grid supply07:00 · budget 120 kW · 6 sessions · ≈20 kW each

Grid supply, a normal morning

The EV budget follows grid headroom: 120 kW is available after the building load, about 20 kW for each of the six cars charging.

Getting started

How backup-power charging is set up

  1. Step 1: Site assessment

    We review the backup system’s rating, the chargers and the site’s load with you and your installer.

  2. Step 2: Agree the limit and conditions

    Your installer specifies the safe backup-power limit from the backup system’s rating and the essential load. It is a configured value that Getz Network enforces; it does not measure the battery. Together we set it and how charging is shared across the bays.

  3. Step 3: Commission and test

    Chargers are commissioned, and outages are rehearsed with the limit in place before a real one arrives.

  4. Step 4: Run and review

    We review charging-profile logs after real outages and adjust the limit if needed.

Questions

Backup-power-aware charging: questions

How does Getz Network know an outage has started?

From the planned outage on record for the site: your team enters the window, or it is created from a work order, for one site or many at once. Automatic schedule import is coming soon.

Who decides the backup-power limit?

You do, with your installer. The limit should leave room for the building’s essential load on backup. Getz Network enforces the limit you configure; it does not size your backup system.

What happens in an outage that is not on record?

Getz Network applies the backup-power limit from the outages on the site’s calendar. If a cut has not been entered, the normal grid-headroom rules stay in force until someone records it. So agree with your installer how the site limit and the protection designed into the backup system cover an unannounced Eskom or municipal cut, and, if the backup system cannot spare any capacity for charging, whether charging during outages suits that site at all. The site assessment covers both.

What if the site also loses its mobile signal?

Limits reach chargers over their data connection. What a charger does while it cannot reach Getz Network depends on its model and configuration, which is checked at commissioning. Edge controllers that keep a site authorising and charging offline are coming soon. For remote lodges and farms, see hotels and game lodges.

Can you promise the backup system will always hold?

No, and you should be wary of anyone who does. Getz Network manages charging within the backup-power limit you configure. Whether the backup system holds also depends on its rating, the building’s other loads and the chargers responding to their profiles, which is why the limit is sized with your installer and rehearsed before the first outage.

Talk to us about charging on backup power

Tell us about your inverter or generator and your chargers, and we will size the limit with you.